 Construction |
 |
 |
 |
| |
|
 |
 |
 |
| 1. |
Protective coating |
| 2. |
Lead weld reinforcing coating |
| 3. |
Lead wire |
| 4. |
Welding point |
| 5. |
Ceramic substrate |
| 6. |
Platinum thin film |
|
|
| |
 |
 |
Features |
| |
 |
 |
| • |
T.C.R.is in accordance with JIS•DIN
standards. |
| • |
The small package with
a real ability of 1k resistance. |
| • |
Thermal time constant is improved with
the small package. |
| • |
Products meet
EU-RoHS requirements.
EU-RoHS regulation is not intended for Pb-glass contained in
glass. |
|
|
|
| |
 |
 |
Applications |
| |
 |
 |
| • |
Detections of outer air temperatures filter
clogging of Air Conditioners. |
| • |
Cold Point compensation and temperature
detection probe for thermocouple temperature controllers. |
| • |
Hot wires and temperature compensation
of anemometers. |
| • |
Temperature compensation and revision
for RF circuit of telecommunication equipment. |
|
|
|
|
Type |
Dimensions(mm) |
Weight(g)
(1000pcs) |
|
W |
L |
t |
f |
d(Nominal) |
 |
| SDT310LTC |
2.0 0.25 |
3.0 0.25 |
1.2max. |
1.1 0.25 |
φ0.2 0.05 |
|
20 |
| SDT310P |
8 2 |
| SDT310MTM |
| SDT310HLTC |
1.2 0.10 |
2.0 0.10
(100 ) |
5.0 0.10
(1k ) |
|
1.1max. |
0.3 0.1 |
|
| SDT310AP |
0.8 0.2 |
3.0 0.25 |
1.2max. |
- |
8 2 |
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| SDT310 |
|
|
|
LT |
|
C |
|
100 |
|
B |
|
3850 |
 |
|
 |
|
 |
|
 |
|
 |
|
 |
|
 |
| Product Code |
|
Size |
|
Temperature Range |
|
Terminal
Surface Material |
|
Nominal Resistance |
|
Class |
|
T.C.R.
(×10-6/K)
 |
| |
|
Nil : standard
H : H style
A : A style |
|
LT : -55
- +155
Nil : -55 - +400
MT : -55 - +650
|
|
C : SnCu(SDT310LT, SDT310HLT)
P : Pt clad wire(SDT310, 310N, 310A)
M : PtIr(SDT310MT)
|
|
100 : 100
500 : 500
1K : 1k
|
|
A : (0.15+0.002|t|) B : (0.3+0.005|t|)
C : (1.0+0.01|t|)
K : 10
(SDT310A) |
|
|
| |
|
|
|
|
|
|
|
|
|
 |
| Contact us when you have control request for environmental hazardous material other than the substance specified by EU-RoHS. |

| Type |
Resistance |
Class*1
: Tolerance of Measuring Temp. |
Resistance Tolerance |
T.C.R.*2
(×10-6/K) |
Thermal
time constant*3 |
Thermal dissipation
constant*3 |
Specified Current*4 |
Operating
Temperature
Range |
| SDT310LTC |
100 ,
500 ,
1k |
A : (0.15+0.002|t|) |
0.059% |
3850 |
7.0s
in stationary air |
0.9mW/ |
1mA max. |
-55
+155 |
B : (0.3+0.005|t|) |
0.12% |
C : (1.0+0.01|t|) |
0.39% |
| SDT310P |
A : (0.3+0.002|t|) |
0.059% |
-55
+400 |
B : (0.3+0.005|t|) |
0.12% |
C : (1.0+0.01|t|) |
0.39% |
| SDT310MTM |
100 |
B : (0.3+0.005|t|) |
0.12% |
-55
+650 |
C : (1.0+0.01|t| |
0.39% |
| SDT310HLTC |
100 , 1k |
A : (0.15+0.002|t|) |
0.059% |
2.8s
in stationary air |
1.0mW/ |
-55 +155 |
B : (0.3+0.005|t|) |
0.12% |
C : (1.0+0.01|t|) |
0.39% |
| SDT310AP |
10 |
- |
10% |
6s
in stationary air |
1.0mW/ |
-55 +400 |
|
 |
*1 |t| is a measuring temperature indicated
at that is not related to marking + • -.
*2 T.C.R.Mesuring Temperature : 0 / +100 
*3 Thermal time constant and dissipation constant are values measured
in stationary air and are typical values,which are values of elements
and vary with connecting or fixing methods.
*4 Specified current is a current value that is used at reliability
test under the condition of self heat- generation that can be disregarded.Recommended
measuring currents are 1mA for 100 and 0.1mA for 500
or 1k .SDT310AP can be used as hot - film sensor . Maximum specifired current is 100mA when using under self - heating condition . |

| |
 |
 |
Temperature Characteristics |
 |
 |
Approximate Expression for Resistance -
Temperature Characteristics
-55 - 0 : RT
=R0 {1 +C1T+C2T2+C3(T-100
)T3} |
0 - +650 : RT
=R0 (1+C1T+C2T2) |
RT : Resistance value
at T |
R0 : Resistance value
at 0 |
T : Ambient temperature ( )
|
| Constants C1
,C2 ,C3
: |
 |
C1
=3.9083 ×10-3 -1
C2 =-5.775 ×10-7 -2
C3 =-4.183 ×10-12 -4
|
|
|
|


|